ZAP-Axon Treatment Planning System

ZAP-Axon is the treatment-planning software for the ZAP-X Radiosurgery System. Medical professionals use it to create, optimize and review radiation plans for tumors, lesions and conditions…

Registry build 21.09.26

ZAP-Axon is the treatment-planning software for the ZAP-X Radiosurgery System. Medical professionals use it to create, optimize and review radiation plans for tumors, lesions and conditions in the brain, head or neck when radiation treatment is indicated.

The application imports and registers imaging studies and can fuse them for planning. The user delineates treatment targets and organs at risk, then calculates and optimizes the radiation dose to create a treatment plan.

Listed Item

The dedicated software application used to create, optimize, and review treatment plans for the ZAP-X Radiosurgery System. It provides the functionalities for the import, registration, and fusion of imaging studies, the delineation of target volumes and organs at risk (OARs), the calculation and optimization of the radiation dose, and the creation of planning reports. The application is installed on dedicated workstations that are directly connected to the other ZAP-X components.

Planning Workstation

ZAP-Axon runs on dedicated workstations connected directly to the other ZAP-X components. It generates planning reports; a separate treatment-delivery application loads and delivers the approved plans.

8manufacturers in China registered for this device type
1catalogue number
4510(k) clearances naming this product code
2recalls on this code

Who Else Makes It

Concentrated in Guangdong (2), Jiangsu (2), Beijing (2). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code IYE
Manufacturer City Province Registered as Device types
Guangzhou Tian Hong Medical Technology Co., Ltd. Guangzhou Guangdong Contract manufacturer 4
Klarity Medical & Equipment (GZ) Co., Ltd. Guangzhou Guangdong Contract manufacturer 3
Elekta Beijing Medical Systems Co., Ltd. Beijing Beijing Contract manufacturer 1
Manteia Technologies Co., Ltd. Xiamen Fujian Manufacturer 3
OUR United Corporation Xian Shaanxi Contract manufacturer 2
Suzhou Linatech Medical Science AND Technology Co., Ltd. Suzhou Jiangsu Manufacturer 2
Varian Medical Systems China Co., Ltd. Beijing Beijing Manufacturer 2
Jiangsu Rayer Medical Technology Co., Ltd. Wuxi Jiangsu Manufacturer 1

Record

Regulatory record for ZAP-Axon Treatment Planning System
Listed by ZAP Surgical Systems Inc., United States
FDA product code IYE
Device type Accelerator, Linear, Medical
Device class Class 2
Regulation 21 CFR 892.5050
Establishment Complaint-file establishment, Manufacturer
510(k) K250392
Record published 2025-11-17

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Label carries serial number

Catalogue Numbers

Catalogue numbers for ZAP-Axon Treatment Planning System
Catalogue number Size Status
300157 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Klarity Medical Klarity Medical Products, LLC 891
Orfit Industries Orfit Industries NV 680
Aquaplast RT™ Qfix 569
Fibreplast® Qfix 271
Bionix Radiation Therapy Bionix Radiation Therapy, LLC 115
Vac-Lok™ Cushion Medtec LLC 100
Visicoil IZI Medical Products LLC 86
BodyFIX 3C-Medical Intelligence GmbH 84
AlignRT Plus Vision RT Limited 72
Fibreplast® Assure™ Open View Qfix 72
Accelerator, Linear, Medical PTW-Freiburg Physikalisch-Technische Werkstätten Dr. Pychlau GmbH 71
Thermoplastic Mask IZI Medical Products LLC 58

Showing 12 of 1,611. All products under Accelerator, Linear, Medical

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K250392 2025-11-03
K211663 2021-07-29
K183698 2019-02-25
K171804 2017-09-21

Recalls

2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2025-07-25 Class II Software change control If the radiosurgery system triggers a proximity error message during a long gantry move (greater-than180 degrees), and a subsequent proximity error message occurs after the automatic reduction of speed, a software defect could potentially l 17
2022-07-05 Class II Software design Software issue identified in cases of initial patient setup with large (greater-than-or-equal-to 1.5 degrees) rotational deviations, between digitally reconstructed radiographs, and pre-delivery X-ray images. In these cases the transitional 8

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer