ClearCalc
ClearCalc RADCA V2.6 is software that performs dose or monitor-unit calculations using treatment, image and structure-set data from supported planning systems. Its stated role is to help…
ClearCalc RADCA V2.6 is software that performs dose or monitor-unit calculations using treatment, image and structure-set data from supported planning systems.
Its stated role is to help radiation-treatment planners independently check whether treatment-planning calculations are accurate.
Listed Item
ClearCalc is a software intended to assist radiation treatment planners in determining if their treatment planning calculations are accurate using an independent Monitor Unit (MU) and dose calculation algorithm.
Version 2.6
Version 2.6 adds support for RayStation and Monaco treatment-planning users through integration with their APIs, as described in the filing. Its common-name field identifies it as secondary-check quality-assurance software.
Who Else Makes It
Concentrated in Jiangsu (2), Fujian (1), Guangdong (1). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Philips Healthcare (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 5 |
| Manteia Technologies Co., Ltd. | Xiamen | Fujian | Manufacturer | 3 |
| Masep Medical Science & Technology DEVELOPMENT(SHENZHEN)Co. | Shenzhen | Guangdong | Manufacturer | 2 |
| Suzhou Linatech Medical Science AND Technology Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 2 |
| Varian Medical Systems China Co., Ltd. | Beijing | Beijing | Manufacturer | 2 |
Record
| Listed by | Radformation, Inc., United States |
|---|---|
| FDA product code | MUJ |
| Device type | System, Planning, Radiation Therapy Treatment |
| Device class | Class 2 |
| Regulation | 21 CFR 892.5050 |
| Establishment | Manufacturer |
| 510(k) | K252863 |
| Record published | 2026-03-13 |
| Record revised | 2026-03-16 (version 2) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| RADCA V2.6 | In distribution | |
| 2.0 | In distribution | |
| Version 2.7 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| RayStation | RaySearch Laboratories AB (publ) | 29 |
| System, Planning, Radiation Therapy Treatment | Nucletron B.V. | 17 |
| Panther TPS | Prowess, Inc. | 14 |
| RayCare | RaySearch Laboratories AB (publ) | 12 |
| Accuray Precision® Treatment Planning System | Accuray Incorporated | 7 |
| Monaco | Elekta Inc. | 7 |
| Eclipse Treatment Planning System for External Beam Radiation Therapy | Varian Medical Systems, Inc | 6 |
| syngo.via RT Image Suite | Siemens Healthcare Limited | 5 |
| Eclipse Treatment Planning System | Varian Medical Systems, Inc | 5 |
| Corvus 09 | Best Nomos | 4 |
| Monaco | Elekta Solutions AB | 4 |
| XKnife® | Integra Lifesciences Corporation | 4 |
Showing 12 of 98. All products under System, Planning, Radiation Therapy Treatment
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K252863 | 2025-12-19 |
| K220582 | 2022-08-22 |
| K193640 | 2020-04-09 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.