RT Elements – Cranial SRS

Catalogue number 3.0, listed by Brainlab SE, Germany, under System, Planning, Radiation Therapy Treatment. 5 manufacturers in China are registered for this product code.

Registry build 21.09.26
5manufacturers in China registered for this device type
1catalogue number
7recalls on this code

Who Else Makes It

Concentrated in Jiangsu (2), Fujian (1), Guangdong (1). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code MUJ
Manufacturer City Province Registered as Device types
Philips Healthcare (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 5
Manteia Technologies Co., Ltd. Xiamen Fujian Manufacturer 3
Masep Medical Science & Technology DEVELOPMENT(SHENZHEN)Co. Shenzhen Guangdong Manufacturer 2
Suzhou Linatech Medical Science AND Technology Co., Ltd. Suzhou Jiangsu Manufacturer 2
Varian Medical Systems China Co., Ltd. Beijing Beijing Manufacturer 2

Record

Regulatory record for RT Elements – Cranial SRS
Listed by Brainlab SE, Germany
FDA product code MUJ
Device type System, Planning, Radiation Therapy Treatment
Device class Class 2
Regulation 21 CFR 892.5050
Establishment Manufacturer, Exporter
510(k) K170750
Record published 2020-11-20
Record revised 2025-09-17 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries lot or batch number

Catalogue Numbers

Catalogue numbers for RT Elements – Cranial SRS
Catalogue number Size Status
3.0 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
RayStation RaySearch Laboratories AB (publ) 29
System, Planning, Radiation Therapy Treatment Nucletron B.V. 17
Panther TPS Prowess, Inc. 14
RayCare RaySearch Laboratories AB (publ) 12
Accuray Precision® Treatment Planning System Accuray Incorporated 7
Monaco Elekta Inc. 7
Eclipse Treatment Planning System for External Beam Radiation Therapy Varian Medical Systems, Inc 6
syngo.via RT Image Suite Siemens Healthcare Limited 5
Eclipse Treatment Planning System Varian Medical Systems, Inc 5
Corvus 09 Best Nomos 4
Monaco Elekta Solutions AB 4
XKnife® Integra Lifesciences Corporation 4

Showing 12 of 98. All products under System, Planning, Radiation Therapy Treatment

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of RT Elements – Cranial SRS
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Brainlab SE 510(k) number 2019-03-11 Class II Device Design There is a potential for an incorrect dose distribution calculation by Brainlab RT Elements software (for affected versions) under specific circumstances when using the Pencil Beam algorithm on the GPU (graphics card), as is the default sys US – 164 units; Outside the US – 333 2021-05-12

Recalls

4 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2015-11-05 Class II Software design Large objects with fine resolution are potentially displayed cropped when imported into Brainlab Brain Metastases 1.0.0. 20 systems 2017-08-21
2015-11-05 Class II Software design Large objects with fine resolution are potentially displayed cropped when imported into Adaptive Hybrid Surgery Analysis version 1.0.0 48 systems 2017-08-21
2014-11-19 Class II Software in the Use Environment iPlan RT Radiation Treatment Planning Software: Potentially incorrect patient positioning when using multiple localized CT image data sets. 1412 systems total 2018-03-28
2014-11-19 Class II Software in the Use Environment iPlan RT Radiation Treatment Planning Software: Potentially incorrect patient positioning when using multiple localized CT image data sets. 1,412 systems total 2018-03-28
2009-08-12 Not classified Other Failure to conduct important safety checks when using the BrainLab radiotherapy treatment planning software in combination with BrainLab conical collimators could result in unintended radiation outside the conical shaped field, which may le 230 units 2011-03-16
2007-11-12 Not classified Component design/selection Diameter of cables used for installation are to small for the applied current. If an internal short circuit is produced the medical power supply will not shut down automatically and will continue to deliver current, which could result in o 23 units 2009-07-24

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer