Biomet® 360 Instrument

36 catalogue numbers from 32-360254, listed by Biomet Orthopedics, United States, under Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uhmwpe, Pegged, Cemented, Polymer/Metal/Polymer. 5 manufacturers in China are registered for this product code.

Registry build 21.09.26
5manufacturers in China registered for this device type
36catalogue numbers in this listing

Who Else Makes It

Concentrated in Shanghai (2), Jiangsu (2), Zhejiang (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code MBV
Manufacturer City Province Registered as Device types
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54

Record

Regulatory record for Biomet® 360 Instrument
Listed by Biomet Orthopedics, United States
FDA product code MBV
Device type Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uhmwpe, Pegged, Cemented, Polymer/Metal/Polymer
Device class Class 2
Regulation 21 CFR 888.3560
510(k) K093293
Record published 2023-07-05
Record revised 2025-05-30 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Prescription Prescription only
Label carries lot or batch number

Catalogue Numbers

Catalogue numbers for Biomet® 360 Instrument
Catalogue number Size Status
32-360254 15 mm X 75 mm In distribution
32-360213 Small In distribution
32-360226 5 mm X 83 mm In distribution
32-360211 5 mm In distribution
32-360221 5 mm X 63 mm In distribution
32-360237 10 mm X 87 mm In distribution
32-360240 15 mm X 59 mm In distribution
32-360214 Large In distribution
32-360258 15 mm X 91 mm In distribution
32-360251 15 mm X 63 mm In distribution
32-360256 15 mm X 83 mm In distribution
32-360207 87 mm In distribution
32-360255 15 mm X 79 mm In distribution
32-360242 15 mm X 67 mm In distribution
32-360233 10 mm X 71 mm In distribution
32-360132 10 mm X 67 mm In distribution
32-360128 5 mm X 91 mm In distribution
32-360252 15 mm X 67 mm In distribution
32-360215 In distribution
32-360225 5 mm X 79 mm In distribution
32-360136 10 mm X 83 mm In distribution
32-360248 15 mm X 91 mm In distribution
32-360212 7.5 mm In distribution
32-360243 15 mm X 71 mm In distribution
32-360224 5 mm X 75 mm In distribution
32-360120 5 mm X 59 mm In distribution
32-360250 15 mm X 59 mm In distribution
32-360123 5 mm X 71 mm In distribution
32-360131 10 mm X 63 mm In distribution
32-360133 10 mm X 71 mm In distribution
32-360134 10 mm X 75 mm In distribution
32-360244 15 mm X 75 mm In distribution
32-360241 15 mm X 63 mm In distribution
32-360222 5 mm X 67 mm In distribution
32-360235 10 mm X 79 mm In distribution
32-360234 10 mm X 75 mm In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Vanguard XP® Instrumentation Biomet Orthopedics 130
Vanguard Complete Knee System Biomet Orthopedics 106
Vanguard® 360 Instrument Biomet Orthopedics 98
Biomet® Knee System Biomet Orthopedics 94
Maxim Knee System Biomet Orthopedics 73
Vanguard Knee System Biomet Orthopedics 49
Vanguard Instrument Biomet Orthopedics 44
Vanguard 360 Revision System Biomet Orthopedics 43
Biomet® 360 Biomet Orthopedics 39
Vanguard 360 Biomet Orthopedics 30
Biomet 360 Knee System Biomet Orthopedics 27
Vanguard® SSK 360 Knee System Biomet Orthopedics 19

Showing 12 of 41. All products under Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uhmwpe, Pegged, Cemented, Polymer/Metal/Polymer

Recalls Naming This Product

5 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Biomet® 360 Instrument
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Biomet, Inc. 510(k) number 2020-12-01 Class II Process control Incorrect bolt -tibial bolts in package instead of femoral bolts may delay procedure 21 units 2022-07-08
Biomet, Inc. 510(k) number 2018-08-02 Class II Under Investigation by firm The implant only has one bolt in the sterile package but it should have had two. 16 2019-04-25
Biomet, Inc. 510(k) number 2018-08-02 Class II Under Investigation by firm The implant only has one bolt in the sterile package but it should have had two. 16 2019-04-25
Biomet, Inc. 510(k) number 2016-08-08 Class II Process control The drill bit used to drill the hex pre-drilled hole in the screw head of the Tibial Augment Bolts included in the Vanguard 360 Revision Knee System was larger than allowable per the process specification. As a result, the hex geometry can 454 2017-06-05
Biomet, Inc. 510(k) number 2014-07-01 Class II Process change control The Vanguard 360 Femoral Boss Reamers were manufactured oversized to the print. The instrument may not fit into the mating component. 461 2015-10-30

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer