Vanguard XP® Instrumentation

130 catalogue numbers from 32-700338, listed by Biomet Orthopedics, United States, under Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uhmwpe, Pegged, Cemented, Polymer/Metal/Polymer. 5 manufacturers in China are registered for this product code.

Registry build 21.09.26
5manufacturers in China registered for this device type
130catalogue numbers in this listing

Who Else Makes It

Concentrated in Shanghai (2), Jiangsu (2), Zhejiang (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code MBV
Manufacturer City Province Registered as Device types
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54

Record

Regulatory record for Vanguard XP® Instrumentation
Listed by Biomet Orthopedics, United States
FDA product code MBV
Device type Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uhmwpe, Pegged, Cemented, Polymer/Metal/Polymer
Device class Class 2
Regulation 21 CFR 888.3560
510(k) K122160
Record published 2021-04-02
Record revised 2025-05-30 (version 7)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Prescription Prescription only
Label carries lot or batch number, manufacturing date

Catalogue Numbers

Catalogue numbers for Vanguard XP® Instrumentation
Catalogue number Size Status
32-700338 10 mm X 91 mm In distribution
32-700398 60 mm In distribution
32-700279 14MM X 91MM In distribution
32-700395 52.5 mm In distribution
32-700082 13 mm 59 mm In distribution
32-700148 9 mm X 59 mm In distribution
32-700182 16 mm X 87/91 mm In distribution
32-700133 16 mm X 69/71/73/75 mm In distribution
32-700087 11MM X 63/65/67MM In distribution
32-700264 13MM X 83MM In distribution
32-700068 87-91 mm In distribution
32-700181 14MM X 87/91MM In distribution
32-700067 69 – 83MM In distribution
32-700278 13MM X 91MM In distribution
32-700079 10 mm 59 mm In distribution
32-700272 14MM X 87MM In distribution
32-700273 16 mm X 87 mm In distribution
32-700140 16 mm X 79/83 mm In distribution
32-700296 10 mm X 65/67 mm In distribution
32-700031 75MM LEFT In distribution
32-700147 16 mm X 87/91 mm In distribution
32-700096 13 mm X 69/71/73/75 mm In distribution
32-700206 11 mm X 79/83 mm In distribution
32-700330 9MM X 87MM In distribution
32-700313 13MM X 73/75MM In distribution
32-700107 10 mm X 87/91 mm In distribution
32-700329 16 mm X 83 mm In distribution
32-700124 13MM X 63/65/67MM In distribution
32-700108 11 mm X 87/91 mm In distribution
32-700038 In distribution
32-700095 12 mm X 69/71/73/75 mm In distribution
32-700234 11 mm X 65/67 mm In distribution
32-700257 13 mm X 79 mm In distribution
32-700062 79MM TIBIAL TRAY TRIAL In distribution
32-700094 11 mm X 69/71/73/75 mm In distribution
32-700065 91 mm In distribution
32-700247 10 mm X 73/75 mm In distribution
32-700333 12 mm X 87 mm In distribution
32-700209 14MM X 79/83MM In distribution
32-700335 14 mm X 87 mm In distribution
32-700213 11MM X 87/91MM In distribution
32-700089 13 mm X 63/65/67 mm In distribution
32-700176 9 mm X 87/91 mm In distribution
32-700181 14 mm X 87/91 mm In distribution
32-700086 10MM X 63/65/67MM In distribution
32-700197 9 mm X 69/71/73/75 mm In distribution
32-700300 14MM X 65/67MM In distribution
32-700325 11 mm X 83 mm In distribution
32-700083 14 mm 59 mm In distribution
32-700174 14 mm X 79/83 mm In distribution
32-700176 9MM X 87/91MM In distribution
32-700259 16MM X 79MM In distribution
32-700072 In distribution
32-700122 11 mm X 63/65/67 mm In distribution
32-700304 11 mm X 69/71 mm In distribution
32-700284 12 mm X 59 mm In distribution
32-700213 11 mm X 87/91 mm In distribution
32-700312 12 mm X 73/75 mm In distribution
32-700215 13MM X 87/91MM In distribution
32-700335 14MM X 87MM In distribution
32-700172 12 mm X 79/83 mm In distribution
32-700247 10MM X 73/75MM In distribution
32-700275 10 mm X 91 mm In distribution
32-700109 12MM X 87/91MM In distribution
32-700110 13MM X 87/91MM In distribution
32-700313 13 mm X 73/75 mm In distribution
32-700290 11MM X 63MM In distribution
32-700014 60MM RIGHT In distribution
32-700161 16MM X 63 / 65 / 67MM In distribution
32-700064 87MM TIBIAL TRAY TRIAL In distribution
32-700204 9 mm X 79/83 mm In distribution
32-700236 13 mm X 65/67 mm In distribution
32-700124 13 mm X 63/65/67 mm In distribution
32-700100 10MM X 79/83MM In distribution
32-700171 11 mm X 79/83 mm In distribution
32-700075 In distribution
32-700081 12 mm 59 mm In distribution
32-700339 11MM X 91MM In distribution
32-700231 16 mm X 63 mm In distribution
32-700200 12 mm X 69/71/73/75 mm In distribution
32-700134 9MM X 79/83MM In distribution
32-700281 9 mm X 59 mm In distribution
32-700230 14MM X 63MM In distribution
32-700012 55MM RIGHT In distribution
32-700189 16 mm X 59 mm In distribution
32-700191 10 mm X 63/65/67 mm In distribution
32-700417 77.5 mm In distribution
32-700340 12 mm X 91 mm In distribution
32-700302 9 mm X 69/71 mm In distribution
32-700317 10 mm X 79 mm In distribution
32-700076 In distribution
32-700222 13 mm X 59 mm In distribution
32-700180 13 mm X 87/91 mm In distribution
32-700269 11MM X 87MM In distribution
32-700139 14 mm X 79/83 mm In distribution
32-700080 11 mm 59 mm In distribution
32-700160 14 mm X 63/65/67 mm In distribution
32-700055 63 mm In distribution
32-700391 In distribution
32-700023 55MM LEFT In distribution
32-700241 11 mm X 69/71 mm In distribution
32-700230 14 mm X 63 mm In distribution
32-700333 12MM X 87MM In distribution
32-700321 14 mm X 79 mm In distribution
32-700316 9 mm X 79 mm In distribution
32-700144 12 mm X 87/91 mm In distribution
32-700256 12 mm X 79 mm In distribution
32-700403 72.5MM, RIGHT In distribution
32-700253 9MM X 79MM In distribution
32-700338 10MM X 91MM In distribution
32-700328 14MM X 83MM In distribution
32-700155 9 mm X 63/65/67 mm In distribution
32-700056 65MM TIBIAL TRAY TRIAL In distribution
32-700263 12 mm X 83 mm In distribution
32-700188 14 mm X 59 mm In distribution
32-700128 10 mm X 69/71/73/75 mm In distribution
32-700268 10MM X 87MM In distribution
32-700266 16MM X 83MM In distribution
32-700235 12MM X 65/67MM In distribution
32-700170 10 mm X 79/83 mm In distribution
32-700061 75 mm In distribution
32-700223 14 mm X 59 mm In distribution
32-700312 12MM X 73/75MM In distribution
32-700287 16 mm X 59 mm In distribution
32-700402 70 mm In distribution
32-700143 11 mm X 87/91 mm In distribution
32-700134 9 mm X 79/83 mm In distribution
32-700112 16 mm X 87/91 mm In distribution
32-700404 75 mm In distribution
32-700175 16 mm X 79/83 mm In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Vanguard Complete Knee System Biomet Orthopedics 106
Vanguard® 360 Instrument Biomet Orthopedics 98
Biomet® Knee System Biomet Orthopedics 94
Maxim Knee System Biomet Orthopedics 73
Vanguard Knee System Biomet Orthopedics 49
Vanguard Instrument Biomet Orthopedics 44
Vanguard 360 Revision System Biomet Orthopedics 43
Biomet® 360 Biomet Orthopedics 39
Biomet® 360 Instrument Biomet Orthopedics 36
Vanguard 360 Biomet Orthopedics 30
Biomet 360 Knee System Biomet Orthopedics 27
Vanguard® SSK 360 Knee System Biomet Orthopedics 19

Showing 12 of 41. All products under Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uhmwpe, Pegged, Cemented, Polymer/Metal/Polymer

Recalls Naming This Product

13 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Vanguard XP® Instrumentation
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 45 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 2 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 8 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 43 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 74 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 123 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 84 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 110 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 99 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 49 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 2021-04-16
Biomet, Inc. 510(k) number 2016-02-05 Class II Device Design The anterior/posterior (AP) dimension may be oversized by 0.016.
If the femoral component does not fit as tightly as intended, bony ingrowth may not occur causing loosening of the femoral component. A revision surgery may be necessary.
890 2017-03-28

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker