Vanguard XP® Instrumentation
130 catalogue numbers from 32-700338, listed by Biomet Orthopedics, United States, under Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uhmwpe, Pegged, Cemented, Polymer/Metal/Polymer. 5 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Shanghai (2), Jiangsu (2), Zhejiang (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
Record
| Listed by | Biomet Orthopedics, United States |
|---|---|
| FDA product code | MBV |
| Device type | Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uhmwpe, Pegged, Cemented, Polymer/Metal/Polymer |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3560 |
| 510(k) | K122160 |
| Record published | 2021-04-02 |
| Record revised | 2025-05-30 (version 7) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Prescription | Prescription only |
| Label carries | lot or batch number, manufacturing date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 32-700338 | 10 mm X 91 mm | In distribution |
| 32-700398 | 60 mm | In distribution |
| 32-700279 | 14MM X 91MM | In distribution |
| 32-700395 | 52.5 mm | In distribution |
| 32-700082 | 13 mm 59 mm | In distribution |
| 32-700148 | 9 mm X 59 mm | In distribution |
| 32-700182 | 16 mm X 87/91 mm | In distribution |
| 32-700133 | 16 mm X 69/71/73/75 mm | In distribution |
| 32-700087 | 11MM X 63/65/67MM | In distribution |
| 32-700264 | 13MM X 83MM | In distribution |
| 32-700068 | 87-91 mm | In distribution |
| 32-700181 | 14MM X 87/91MM | In distribution |
| 32-700067 | 69 – 83MM | In distribution |
| 32-700278 | 13MM X 91MM | In distribution |
| 32-700079 | 10 mm 59 mm | In distribution |
| 32-700272 | 14MM X 87MM | In distribution |
| 32-700273 | 16 mm X 87 mm | In distribution |
| 32-700140 | 16 mm X 79/83 mm | In distribution |
| 32-700296 | 10 mm X 65/67 mm | In distribution |
| 32-700031 | 75MM LEFT | In distribution |
| 32-700147 | 16 mm X 87/91 mm | In distribution |
| 32-700096 | 13 mm X 69/71/73/75 mm | In distribution |
| 32-700206 | 11 mm X 79/83 mm | In distribution |
| 32-700330 | 9MM X 87MM | In distribution |
| 32-700313 | 13MM X 73/75MM | In distribution |
| 32-700107 | 10 mm X 87/91 mm | In distribution |
| 32-700329 | 16 mm X 83 mm | In distribution |
| 32-700124 | 13MM X 63/65/67MM | In distribution |
| 32-700108 | 11 mm X 87/91 mm | In distribution |
| 32-700038 | In distribution | |
| 32-700095 | 12 mm X 69/71/73/75 mm | In distribution |
| 32-700234 | 11 mm X 65/67 mm | In distribution |
| 32-700257 | 13 mm X 79 mm | In distribution |
| 32-700062 | 79MM TIBIAL TRAY TRIAL | In distribution |
| 32-700094 | 11 mm X 69/71/73/75 mm | In distribution |
| 32-700065 | 91 mm | In distribution |
| 32-700247 | 10 mm X 73/75 mm | In distribution |
| 32-700333 | 12 mm X 87 mm | In distribution |
| 32-700209 | 14MM X 79/83MM | In distribution |
| 32-700335 | 14 mm X 87 mm | In distribution |
| 32-700213 | 11MM X 87/91MM | In distribution |
| 32-700089 | 13 mm X 63/65/67 mm | In distribution |
| 32-700176 | 9 mm X 87/91 mm | In distribution |
| 32-700181 | 14 mm X 87/91 mm | In distribution |
| 32-700086 | 10MM X 63/65/67MM | In distribution |
| 32-700197 | 9 mm X 69/71/73/75 mm | In distribution |
| 32-700300 | 14MM X 65/67MM | In distribution |
| 32-700325 | 11 mm X 83 mm | In distribution |
| 32-700083 | 14 mm 59 mm | In distribution |
| 32-700174 | 14 mm X 79/83 mm | In distribution |
| 32-700176 | 9MM X 87/91MM | In distribution |
| 32-700259 | 16MM X 79MM | In distribution |
| 32-700072 | In distribution | |
| 32-700122 | 11 mm X 63/65/67 mm | In distribution |
| 32-700304 | 11 mm X 69/71 mm | In distribution |
| 32-700284 | 12 mm X 59 mm | In distribution |
| 32-700213 | 11 mm X 87/91 mm | In distribution |
| 32-700312 | 12 mm X 73/75 mm | In distribution |
| 32-700215 | 13MM X 87/91MM | In distribution |
| 32-700335 | 14MM X 87MM | In distribution |
| 32-700172 | 12 mm X 79/83 mm | In distribution |
| 32-700247 | 10MM X 73/75MM | In distribution |
| 32-700275 | 10 mm X 91 mm | In distribution |
| 32-700109 | 12MM X 87/91MM | In distribution |
| 32-700110 | 13MM X 87/91MM | In distribution |
| 32-700313 | 13 mm X 73/75 mm | In distribution |
| 32-700290 | 11MM X 63MM | In distribution |
| 32-700014 | 60MM RIGHT | In distribution |
| 32-700161 | 16MM X 63 / 65 / 67MM | In distribution |
| 32-700064 | 87MM TIBIAL TRAY TRIAL | In distribution |
| 32-700204 | 9 mm X 79/83 mm | In distribution |
| 32-700236 | 13 mm X 65/67 mm | In distribution |
| 32-700124 | 13 mm X 63/65/67 mm | In distribution |
| 32-700100 | 10MM X 79/83MM | In distribution |
| 32-700171 | 11 mm X 79/83 mm | In distribution |
| 32-700075 | In distribution | |
| 32-700081 | 12 mm 59 mm | In distribution |
| 32-700339 | 11MM X 91MM | In distribution |
| 32-700231 | 16 mm X 63 mm | In distribution |
| 32-700200 | 12 mm X 69/71/73/75 mm | In distribution |
| 32-700134 | 9MM X 79/83MM | In distribution |
| 32-700281 | 9 mm X 59 mm | In distribution |
| 32-700230 | 14MM X 63MM | In distribution |
| 32-700012 | 55MM RIGHT | In distribution |
| 32-700189 | 16 mm X 59 mm | In distribution |
| 32-700191 | 10 mm X 63/65/67 mm | In distribution |
| 32-700417 | 77.5 mm | In distribution |
| 32-700340 | 12 mm X 91 mm | In distribution |
| 32-700302 | 9 mm X 69/71 mm | In distribution |
| 32-700317 | 10 mm X 79 mm | In distribution |
| 32-700076 | In distribution | |
| 32-700222 | 13 mm X 59 mm | In distribution |
| 32-700180 | 13 mm X 87/91 mm | In distribution |
| 32-700269 | 11MM X 87MM | In distribution |
| 32-700139 | 14 mm X 79/83 mm | In distribution |
| 32-700080 | 11 mm 59 mm | In distribution |
| 32-700160 | 14 mm X 63/65/67 mm | In distribution |
| 32-700055 | 63 mm | In distribution |
| 32-700391 | In distribution | |
| 32-700023 | 55MM LEFT | In distribution |
| 32-700241 | 11 mm X 69/71 mm | In distribution |
| 32-700230 | 14 mm X 63 mm | In distribution |
| 32-700333 | 12MM X 87MM | In distribution |
| 32-700321 | 14 mm X 79 mm | In distribution |
| 32-700316 | 9 mm X 79 mm | In distribution |
| 32-700144 | 12 mm X 87/91 mm | In distribution |
| 32-700256 | 12 mm X 79 mm | In distribution |
| 32-700403 | 72.5MM, RIGHT | In distribution |
| 32-700253 | 9MM X 79MM | In distribution |
| 32-700338 | 10MM X 91MM | In distribution |
| 32-700328 | 14MM X 83MM | In distribution |
| 32-700155 | 9 mm X 63/65/67 mm | In distribution |
| 32-700056 | 65MM TIBIAL TRAY TRIAL | In distribution |
| 32-700263 | 12 mm X 83 mm | In distribution |
| 32-700188 | 14 mm X 59 mm | In distribution |
| 32-700128 | 10 mm X 69/71/73/75 mm | In distribution |
| 32-700268 | 10MM X 87MM | In distribution |
| 32-700266 | 16MM X 83MM | In distribution |
| 32-700235 | 12MM X 65/67MM | In distribution |
| 32-700170 | 10 mm X 79/83 mm | In distribution |
| 32-700061 | 75 mm | In distribution |
| 32-700223 | 14 mm X 59 mm | In distribution |
| 32-700312 | 12MM X 73/75MM | In distribution |
| 32-700287 | 16 mm X 59 mm | In distribution |
| 32-700402 | 70 mm | In distribution |
| 32-700143 | 11 mm X 87/91 mm | In distribution |
| 32-700134 | 9 mm X 79/83 mm | In distribution |
| 32-700112 | 16 mm X 87/91 mm | In distribution |
| 32-700404 | 75 mm | In distribution |
| 32-700175 | 16 mm X 79/83 mm | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Vanguard Complete Knee System | Biomet Orthopedics | 106 |
| Vanguard® 360 Instrument | Biomet Orthopedics | 98 |
| Biomet® Knee System | Biomet Orthopedics | 94 |
| Maxim Knee System | Biomet Orthopedics | 73 |
| Vanguard Knee System | Biomet Orthopedics | 49 |
| Vanguard Instrument | Biomet Orthopedics | 44 |
| Vanguard 360 Revision System | Biomet Orthopedics | 43 |
| Biomet® 360 | Biomet Orthopedics | 39 |
| Biomet® 360 Instrument | Biomet Orthopedics | 36 |
| Vanguard 360 | Biomet Orthopedics | 30 |
| Biomet 360 Knee System | Biomet Orthopedics | 27 |
| Vanguard® SSK 360 Knee System | Biomet Orthopedics | 19 |
Showing 12 of 41. All products under Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uhmwpe, Pegged, Cemented, Polymer/Metal/Polymer
Recalls Naming This Product
13 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 45 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 2 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 8 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 43 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 74 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 123 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 2021-04-16 | |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 84 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 110 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 99 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 49 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 2021-04-16 | |
| Biomet, Inc. | 510(k) number | 2016-02-05 | Class II | Device Design | The anterior/posterior (AP) dimension may be oversized by 0.016. If the femoral component does not fit as tightly as intended, bony ingrowth may not occur causing loosening of the femoral component. A revision surgery may be necessary. | 890 | 2017-03-28 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.