Who Else Makes It

Concentrated in Shanghai (2), Jiangsu (2), Zhejiang (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code MBV
Manufacturer City Province Registered as Device types
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54

Record

Regulatory record for Biomet® Knee System
Listed by Biomet Orthopedics, United States
FDA product code MBV
Device type Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uhmwpe, Pegged, Cemented, Polymer/Metal/Polymer
Device class Class 2
Regulation 21 CFR 888.3560
510(k) K142933
Record published 2015-10-24
Record revised 2026-04-27 (version 8)

Specifications

Specifications
MRI safety MR Conditional
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date

Catalogue Numbers

Catalogue numbers for Biomet® Knee System
Catalogue number Size Status
148202 12 MM 160 MM In distribution
185187 23 mm In distribution
141493 In distribution
148152 22 MM 40 MM In distribution
141220 59 mm Length In distribution
148160 10 MM 80 MM In distribution
145048 18 MM 120 MM In distribution
148184 14 MM 120 MM In distribution
145046 16 MM 120 MM In distribution
145088 18 MM 200 MM In distribution
141742 6 MM 67 MM In distribution
141215 79 MM In distribution
148226 16 MM 200 MM In distribution
141511 63 MM In distribution
148172 22 MM 80 MM In distribution
141746 6 MM 83 MM In distribution
141220 59 MM In distribution
141236 83 MM In distribution
141781 LM/RL 16 mm 63 mm In distribution
141225 79 mm In distribution
141227 87 mm In distribution
141490 2.5 MM In distribution
148146 16 MM 40 MM In distribution
141487 87 MM In distribution
141872 12 MM 160 MM In distribution
141513 71 MM In distribution
148024 14 MM 200 MM In distribution
141713 4 MM 71 MM In distribution
141510 59 mm In distribution
141268 91 MM In distribution
141217 87 mm In distribution
148208 18 MM 160 MM In distribution
148002 12 MM 160 MM In distribution
141768 10 MM 91 MM In distribution
141783 LM/RL 16 mm 71 mm In distribution
145030 20 MM 80 MM In distribution
141896 16 MM 200 MM In distribution
145034 24 MM 80 MM In distribution
148190 20 MM 120 MM In distribution
141210 59 MM In distribution
141237 87 mm In distribution
141743 6 MM 71 MM In distribution
141488 91 MM In distribution
141211 63 mm In distribution
141766 10 MM 83 MM In distribution
141512 67 mm In distribution
141514 75 mm In distribution
141792 RM/LL 16 mm 67 mm In distribution
141232 67 mm In distribution
141238 91 MM In distribution
141227 87 MM In distribution
141483 71 MM In distribution
141761 10 MM 63 MM In distribution
141314 40 mm In distribution
145090 20 MM 200 MM In distribution
141710 4 MM 59 MM In distribution
141492 In distribution
11-150824 Large 37 mm In distribution
141480 59 MM In distribution
148174 24 MM 80 MM In distribution
141262 67 mm In distribution
141798 RM/LL 16 mm 91 mm In distribution
145014 24 MM 40 MM In distribution
141483 71 MM In distribution
148028 18 MM 200 MM In distribution
141218 91 MM In distribution
141488 91 MM In distribution
141262 67 MM In distribution
141512 67 mm In distribution
141900 20 MM 200 MM In distribution
148188 18 MM 120 MM In distribution
141717 4 MM 87 MM In distribution
141495 2.5 MM In distribution
148030 20 MM 200 MM In distribution
145072 22 MM 160 MM In distribution
148140 10 MM 40 MM In distribution
141491 5 mm In distribution
141765 10 MM 79 MM In distribution
145000 10 MM 40 MM In distribution
141487 87 MM In distribution
141744 6 MM 75 MM In distribution
141880 20 MM 160 MM In distribution
145082 12 MM 200 MM In distribution
141217 87 mm In distribution
141496 5 mm In distribution
148204 14 MM 160 MM In distribution
141481 63 MM In distribution
148006 16 MM 160 MM In distribution
141898 18 MM 200 MM In distribution
141786 LM/RL 16 mm 83 mm In distribution
141494 NEUTRAL SIZE In distribution
148268 18 MM 200 MM In distribution
CP102890 15 MM 60 MM In distribution
148186 16 MM 120 MM In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Vanguard XP® Instrumentation Biomet Orthopedics 130
Vanguard Complete Knee System Biomet Orthopedics 106
Vanguard® 360 Instrument Biomet Orthopedics 98
Maxim Knee System Biomet Orthopedics 73
Vanguard Knee System Biomet Orthopedics 49
Vanguard Instrument Biomet Orthopedics 44
Vanguard 360 Revision System Biomet Orthopedics 43
Biomet® 360 Biomet Orthopedics 39
Biomet® 360 Instrument Biomet Orthopedics 36
Vanguard 360 Biomet Orthopedics 30
Biomet 360 Knee System Biomet Orthopedics 27
Vanguard® SSK 360 Knee System Biomet Orthopedics 19

Showing 12 of 41. All products under Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uhmwpe, Pegged, Cemented, Polymer/Metal/Polymer

Recalls Naming This Product

19 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Biomet® Knee System
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Biomet, Inc. 510(k) number 2022-12-29 Class II Labeling Change Control Components Incorrectly labeled as either smaller or larger and incorrect side (right/left). 157 units
Biomet, Inc. 510(k) number 2022-12-29 Class II Labeling Change Control Components Incorrectly labeled as either smaller or larger and incorrect side (right/left). 91 units
Biomet, Inc. 510(k) number 2020-04-17 Class II Process control Potential presence of elevated endotoxin levels that exceed the specification limit 54 units 2021-06-25
Biomet, Inc. 510(k) number 2018-12-21 Class II Under Investigation by firm Vanguard Knee System Series-A Standard Patella a potential commingle that could result in the size of the implant not matching the size on the label. 90 units 2020-05-13
Biomet, Inc. 510(k) number 2018-10-22 Class II Labeling mix-ups Label on the outer carton or the patient labels does not match label on the inner sterile packaging 8 units 2019-12-11
Biomet, Inc. 510(k) number 2018-10-22 Class II Labeling mix-ups Label on the outer carton or the patient labels does not match label on the inner sterile packaging 8 units 2019-12-11
Biomet, Inc. 510(k) number 2018-05-24 Class II Under Investigation by firm Two lots of tibial bearings were commingled. There is a possibility that a 14mm tibial bearing is packaged in a box labeled as 12 mm tibial bearing and vice versa. This may lead to extension of surgery to find another implant. 48 2020-04-07
Biomet, Inc. 510(k) number 2018-05-18 Class II Under Investigation by firm One lot of 75mm tibial tray is potentially etched and labeled as a 79 mm tibial tray. This may lead to delay in surgery, or immediate revision surgery to remove an incorrectly sized tibial component after it has been cemented. 16 2020-03-31
Biomet, Inc. 510(k) number 2018-05-11 Class II Under Investigation by firm The label master file was errantly set up as a 63/37mm instead of a 63/67mm. There is no 63/37 size offered, and the product is laser marked with the correct size. 169 2019-11-21
Biomet, Inc. 510(k) number 2017-10-03 Class II Error in labeling The affected products are labeled as a 62.5mm LEFT Femur; however, the contents are a Vanguard 70mm RIGHT Femur. 8 2018-08-23
Biomet, Inc. 510(k) number 2016-12-15 Class II Material/Component Contamination Zimmer Biomet is conducting a medical device recall for ARCOS & TPRLC broaches and rasps due to potential alumina inclusions in the raw material batch used to produce the affected products. Inclusions contained within the finished product c 26 2018-06-29
Biomet, Inc. 510(k) number 2015-04-16 Class III Labeling mix-ups Biomet hip joint, knee joint and shoulder joint replacement components device labeling contains incorrect GTIN (Global Trade Identification Number) codes. 1315 2016-05-16
Biomet, Inc. 510(k) number 2012-11-15 Class II Employee error Biomet investigation identified that the square end of the offset tibial tray adaptor locking insert is oversized and may not engage insert tool screwdriver. This could cause a possible delay in surgery greater than 30 minutes, potentiall 200 2013-11-08
Biomet, Inc. 510(k) number 2011-03-03 Not classified Packaging process control The firm is recalling the product due to the product’s packaging being labeled “I-Beam 75mm. Tibial Plate”, but the package actually contains the “Interlok 67mm. CR Tibial Plate”. 8 2011-07-27
Biomet, Inc. 510(k) number 2007-12-12 Not classified Packaging process control Mislabeled as to size: Package labeled as containing a 67 mm tray actually contains a 75 mm tray and vice versa. 8 2008-06-11
Biomet, Inc. 510(k) number 2007-12-12 Not classified Packaging process control Mislabeled as to size: Package labeled as containing a 67 mm tray actually contains a 75 mm tray and vice versa. 8 2008-06-11
Biomet, Inc. 510(k) number 2007-09-18 Not classified Labeling mix-ups Mislabeled as to size: the package actaully contained a 71 mm tray. 7 2008-06-04
Biomet, Inc. 510(k) number 2007-07-24 Not classified Labeling mix-ups Incorrect Product — Mislabeled as to size; a 18 mm x 65 mm tibula implant is enclosed in a package labeled as 12 mm x 80 mm. 4 2008-07-24
Biomet, Inc. 510(k) number 2007-07-24 Not classified Labeling mix-ups Incorrect Product — Mislabeled as to size; a 18 mm x 65 mm tibula implant is enclosed in a package labeled as 12 mm x 80 mm. 1 2008-07-24

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer