Vanguard Complete Knee System
106 catalogue numbers from 195911, listed by Biomet Orthopedics, United States, under Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uhmwpe, Pegged, Cemented, Polymer/Metal/Polymer. 5 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Shanghai (2), Jiangsu (2), Zhejiang (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
Record
| Listed by | Biomet Orthopedics, United States |
|---|---|
| FDA product code | MBV |
| Device type | Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uhmwpe, Pegged, Cemented, Polymer/Metal/Polymer |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3560 |
| 510(k) | K141407 |
| Record published | 2015-10-24 |
| Record revised | 2025-05-30 (version 7) |
Specifications
| MRI safety | MR Conditional |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 195911 | 67.5 MM | In distribution |
| 195544 | 11MM THICKNESS 65/67 TRAY | In distribution |
| 195947 | 67.5 MM | In distribution |
| 195550 | 10MM THICKNESS 69/71 TRAY | In distribution |
| 195837 | 11MM THICKNESS 59 TRAY | In distribution |
| 195629 | 12MM THICKNESS 79MM TRAY | In distribution |
| 195289 | 83 MM | In distribution |
| 195628 | 11MM THICKNESS 79MM TRAY | In distribution |
| 195914 | 75 MM | In distribution |
| 195924 | 70 MM | In distribution |
| 195874 | 13MM THICKNESS 59 TRAY | In distribution |
| 195873 | 12MM THICKNESS 59 TRAY | In distribution |
| 195630 | 13MM THICKNESS 79MM TRAY | In distribution |
| 195283 | 67 MM | In distribution |
| 195855 | 16MM THICKNESS 69/71/73/75 TRAY | In distribution |
| 195562 | 16MM THICKNESS 73/75 TRAY | In distribution |
| 195841 | 16MM THICKNESS 59 TRAY | In distribution |
| 195860 | 13MM THICKNESS 79/83 TRAY | In distribution |
| 195822 | 10MM THICKNESS 79/83 TRAY | In distribution |
| 195849 | 9MM THICKNESS 69/71/73/75 TRAY | In distribution |
| 195933 | 62.5 MM | In distribution |
| 195944 | 60 MM | In distribution |
| 195840 | 14MM THICKNESS 59 TRAY | In distribution |
| 195869 | 16MM THICKNESS 87/91 TRAY | In distribution |
| 195590 | 16MM THICKNESS 91MM TRAY | In distribution |
| 195615 | 12MM THICKNESS 69/71 TRAY | In distribution |
| 195614 | 11MM THICKNESS 69/71 TRAY | In distribution |
| 195633 | 9MM THICKNESS 83MM TRAY | In distribution |
| 195530 | 11MM THICKNESS 59MM TRAY | In distribution |
| 195574 | 13MM THICKNESS 83MM TRAY | In distribution |
| 195577 | 9MM THICKNESS 87MM TRAY | In distribution |
| 195281 | 63 MM | In distribution |
| 195652 | 14MM THICKNESS 91MM TRAY | In distribution |
| 195641 | 10MM THICKNESS 87MM TRAY | In distribution |
| 195640 | 9MM THICKNESS 87MM TRAY | In distribution |
| 195912 | 70 MM | In distribution |
| 195572 | 11MM THICKNESS 83MM TRAY | In distribution |
| 195611 | 16MM THICKNESS 65/67 TRAY | In distribution |
| 195871 | 10MM THICKNESS 59 TRAY | In distribution |
| 195846 | 13MM THICKNESS 63/65/67 TRAY | In distribution |
| 195779 | 9MM THICKNESS 69/71/73/75 TRAY | In distribution |
| 195585 | 10MM THICKNESS 91MM TRAY | In distribution |
| 195560 | 13MM THICKNESS 73/75 TRAY | In distribution |
| 195573 | 12MM THICKNESS 83MM TRAY | In distribution |
| 195632 | 16MM THICKNESS 79MM TRAY | In distribution |
| 195929 | 52.5 MM | In distribution |
| 195541 | 16MM THICKNESS 63MM TRAY | In distribution |
| 195612 | 9MM THICKNESS 69/71 TRAY | In distribution |
| 195602 | 13MM THICKNESS 63MM TRAY | In distribution |
| 195548 | 16MM THICKNESS 65/67 TRAY | In distribution |
| 195895 | 13MM THICKNESS 79/83 TRAY | In distribution |
| 195598 | 9MM THICKNESS 63MM TRAY | In distribution |
| 195796 | 12MM THICKNESS 87/91 TRAY | In distribution |
| 195628 | 11MM THICKNESS 79MM TRAY | In distribution |
| 195279 | 91 MM | In distribution |
| 195757 | 75 MM | In distribution |
| 195552 | 12MM THICKNESS 69/71 TRAY | In distribution |
| 195553 | 13MM THICKNESS 69/71 TRAY | In distribution |
| 195593 | 11MM THICKNESS 59MM TRAY | In distribution |
| 195908 | 60 MM | In distribution |
| 195926 | 75 MM | In distribution |
| 195626 | 9MM THICKNESS 79MM TRAY | In distribution |
| 195287 | 75 MM | In distribution |
| 195290 | 87 MM | In distribution |
| 195565 | 11MM THICKNESS 79MM TRAY | In distribution |
| 195621 | 11MM THICKNESS 73/75 TRAY | In distribution |
| 195828 | 9MM THICKNESS 87/91 TRAY | In distribution |
| 195564 | 10MM THICKNESS 79MM TRAY | In distribution |
| 195864 | 10MM THICKNESS 87/91 TRAY | In distribution |
| 195632 | 16MM THICKNESS 79MM TRAY | In distribution |
| 195547 | 14MM THICKNESS 65/67 TRAY | In distribution |
| 195571 | 10MM THICKNESS 83MM TRAY | In distribution |
| 195627 | 10MM THICKNESS 79MM TRAY | In distribution |
| 195602 | 13MM THICKNESS 63MM TRAY | In distribution |
| 195867 | 13MM THICKNESS 87/91 TRAY | In distribution |
| 195857 | 10MM THICKNESS 79/83 TRAY | In distribution |
| 195605 | 9MM THICKNESS 65/67 TRAY | In distribution |
| 195809 | 11MM THICKNESS 63/65/67 TRAY | In distribution |
| 195568 | 14MM THICKNESS 79MM TRAY | In distribution |
| 195620 | 10MM THICKNESS 73/75 TRAY | In distribution |
| 195897 | 16MM THICKNESS 79/83 TRAY | In distribution |
| 195847 | 14MM THICKNESS 63/65/67 TRAY | In distribution |
| 195555 | 16MM THICKNESS 69/71 TRAY | In distribution |
| 195825 | 13MM THICKNESS 79/83 TRAY | In distribution |
| 195583 | 16MM THICKNESS 87MM TRAY | In distribution |
| 195787 | 10MM THICKNESS 79/83 TRAY | In distribution |
| 195892 | 10MM THICKNESS 79/83 TRAY | In distribution |
| 195939 | 77.5 MM | In distribution |
| 195577 | 9MM THICKNESS 87MM TRAY | In distribution |
| 195614 | 11MM THICKNESS 69/71 TRAY | In distribution |
| 195575 | 14MM THICKNESS 83MM TRAY | In distribution |
| 195913 | 72.5 MM | In distribution |
| 195545 | 12MM THICKNESS 65/67 TRAY | In distribution |
| 195763 | 69/71 MM 73/75 MM | In distribution |
| 195582 | 14MM THICKNESS 87MM TRAY | In distribution |
| 195918 | 55 MM | In distribution |
| 195623 | 13MM THICKNESS 73/75 TRAY | In distribution |
| 195834 | 16MM THICKNESS 87/91 TRAY | In distribution |
| 195540 | 14MM THICKNESS 63MM TRAY | In distribution |
| 195833 | 14MM THICKNESS 87/91 TRAY | In distribution |
| 195891 | 9MM THICKNESS 79/83 TRAY | In distribution |
| 195885 | 10MM THICKNESS 69/71/73/75 TRAY | In distribution |
| 195546 | 13MM THICKNESS 65/67 TRAY | In distribution |
| 195615 | 12MM THICKNESS 69/71 TRAY | In distribution |
| 195755 | 71 MM | In distribution |
| 195771 | 16MM THICKNESS 59MM TRAY | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Vanguard XP® Instrumentation | Biomet Orthopedics | 130 |
| Vanguard® 360 Instrument | Biomet Orthopedics | 98 |
| Biomet® Knee System | Biomet Orthopedics | 94 |
| Maxim Knee System | Biomet Orthopedics | 73 |
| Vanguard Knee System | Biomet Orthopedics | 49 |
| Vanguard Instrument | Biomet Orthopedics | 44 |
| Vanguard 360 Revision System | Biomet Orthopedics | 43 |
| Biomet® 360 | Biomet Orthopedics | 39 |
| Biomet® 360 Instrument | Biomet Orthopedics | 36 |
| Vanguard 360 | Biomet Orthopedics | 30 |
| Biomet 360 Knee System | Biomet Orthopedics | 27 |
| Vanguard® SSK 360 Knee System | Biomet Orthopedics | 19 |
Showing 12 of 41. All products under Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uhmwpe, Pegged, Cemented, Polymer/Metal/Polymer
Recalls Naming This Product
35 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 45 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 322 unit | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 375 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 567 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 498 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 454 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 327 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 369 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 319 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 180 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 78 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 82 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 2 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 86 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 90 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 384 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 2021-04-16 | |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 973 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 906 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 1221 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 1282 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 1210 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 857 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 480 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 8 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 43 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 74 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 123 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 2021-04-16 | |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 84 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 110 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 99 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 49 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 2021-04-16 | |
| Biomet, Inc. | 510(k) number | 2016-02-05 | Class II | Device Design | The anterior/posterior (AP) dimension may be oversized by 0.016. If the femoral component does not fit as tightly as intended, bony ingrowth may not occur causing loosening of the femoral component. A revision surgery may be necessary. | 890 | 2017-03-28 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.