Vanguard XP® Complete Knee System
12 catalogue numbers from 195905, listed by Biomet Orthopedics, United States, under Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uhmwpe, Pegged, Cemented, Polymer/Metal/Polymer. 5 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Shanghai (2), Jiangsu (2), Zhejiang (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
Record
| Listed by | Biomet Orthopedics, United States |
|---|---|
| FDA product code | MBV |
| Device type | Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uhmwpe, Pegged, Cemented, Polymer/Metal/Polymer |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3560 |
| 510(k) | K141407 |
| Record published | 2026-01-08 |
Specifications
| MRI safety | MR Conditional |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 195905 | 52.5 MM | In distribution |
| 195927 | 77.5 MM | In distribution |
| 195919 | 57.5 MM | In distribution |
| 195917 | 52.5 MM | In distribution |
| 195753 | 67 MM | In distribution |
| 195908 | 60 MM | In distribution |
| 195906 | 55 MM | In distribution |
| 195755 | 71 MM | In distribution |
| 195762 | 59/63 MM 65/67 MM | In distribution |
| 195277 | 83 MM | In distribution |
| 195276 | 79 MM | In distribution |
| 195910 | 65 MM | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Vanguard XP® Instrumentation | Biomet Orthopedics | 130 |
| Vanguard Complete Knee System | Biomet Orthopedics | 106 |
| Vanguard® 360 Instrument | Biomet Orthopedics | 98 |
| Biomet® Knee System | Biomet Orthopedics | 94 |
| Maxim Knee System | Biomet Orthopedics | 73 |
| Vanguard Knee System | Biomet Orthopedics | 49 |
| Vanguard Instrument | Biomet Orthopedics | 44 |
| Vanguard 360 Revision System | Biomet Orthopedics | 43 |
| Biomet® 360 | Biomet Orthopedics | 39 |
| Biomet® 360 Instrument | Biomet Orthopedics | 36 |
| Vanguard 360 | Biomet Orthopedics | 30 |
| Biomet 360 Knee System | Biomet Orthopedics | 27 |
Showing 12 of 41. All products under Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uhmwpe, Pegged, Cemented, Polymer/Metal/Polymer
Recalls Naming This Product
23 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 322 unit | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 375 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 567 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 498 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 454 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 327 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 369 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 319 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 180 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 78 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 82 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 86 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 90 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 384 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 2021-04-16 | |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 973 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 906 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 1221 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 1282 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 1210 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 857 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2019-08-15 | Class II | Manufacturing material removal | The locking bar not fully engaging | 480 units | 2021-04-16 |
| Biomet, Inc. | 510(k) number | 2016-02-05 | Class II | Device Design | The anterior/posterior (AP) dimension may be oversized by 0.016. If the femoral component does not fit as tightly as intended, bony ingrowth may not occur causing loosening of the femoral component. A revision surgery may be necessary. | 890 | 2017-03-28 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.