Vanguard XP

13 catalogue numbers from 32-700094, listed by Biomet Orthopedics, United States, under Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uhmwpe, Pegged, Cemented, Polymer/Metal/Polymer. 5 manufacturers in China are registered for this product code.

Registry build 21.09.26
5manufacturers in China registered for this device type
13catalogue numbers in this listing

Who Else Makes It

Concentrated in Shanghai (2), Jiangsu (2), Zhejiang (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code MBV
Manufacturer City Province Registered as Device types
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54

Record

Regulatory record for Vanguard XP
Listed by Biomet Orthopedics, United States
FDA product code MBV
Device type Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uhmwpe, Pegged, Cemented, Polymer/Metal/Polymer
Device class Class 2
Regulation 21 CFR 888.3560
510(k) K122160
Record published 2016-10-25
Record revised 2025-05-30 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Prescription Prescription only
Label carries lot or batch number, manufacturing date

Catalogue Numbers

Catalogue numbers for Vanguard XP
Catalogue number Size Status
32-700094 11MM X 69/71/73/75MM In distribution
32-700204 9MM X 79/83MM In distribution
32-700158 12MM X 63/65/67MM In distribution
32-700098 16MM X 69 / 71 / 73 / 75MM In distribution
32-700092 9MM X 69/71/73/75MM In distribution
32-700093 10MM X 69/71/73/75MM In distribution
32-700038 In distribution
32-700166 13MM X 69/71/73/75MM In distribution
32-700096 13MM X 69/71/73/75MM In distribution
32-700366 In distribution
32-700208 13MM X 79/83MM In distribution
32-700280 16MM X 91MM In distribution
32-700201 13MM X 69/71/73/75MM In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Vanguard XP® Instrumentation Biomet Orthopedics 130
Vanguard Complete Knee System Biomet Orthopedics 106
Vanguard® 360 Instrument Biomet Orthopedics 98
Biomet® Knee System Biomet Orthopedics 94
Maxim Knee System Biomet Orthopedics 73
Vanguard Knee System Biomet Orthopedics 49
Vanguard Instrument Biomet Orthopedics 44
Vanguard 360 Revision System Biomet Orthopedics 43
Biomet® 360 Biomet Orthopedics 39
Biomet® 360 Instrument Biomet Orthopedics 36
Vanguard 360 Biomet Orthopedics 30
Biomet 360 Knee System Biomet Orthopedics 27

Showing 12 of 41. All products under Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uhmwpe, Pegged, Cemented, Polymer/Metal/Polymer

Recalls Naming This Product

12 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Vanguard XP
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 45 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 2 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 8 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 43 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 74 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 123 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 84 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 110 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 99 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 49 units 2021-04-16
Biomet, Inc. 510(k) number 2019-08-15 Class II Manufacturing material removal The locking bar not fully engaging 2021-04-16

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer